FD20 WHG/LAU-mortar

ready-to-use repair mortar for facilities for storing, bottling and processing liquids hazardous to water in accordance to ZTV-ING part 3, section 4, DAfStb directive SIB M3 und DIN EN 1504-3 for structurally relevant purposes

  • concrete repair in accordance with ZTV-ING part 3
  • restoration of impermeability to fluids of concrete constructions in facilities for storage, bottling or processing liquids hazardous to water
  • reduces the penetration of CO2
  • construction material A1 (non -flammable) in accordance with DIN EN 13501
  • RM02: corrosion protection and bonding bridge
  • granularity: 0-2 mm
  • layer thickness: 10-50 mm
  • consumption: 1,85 kg/(m²⋅mm)
  • processing time at 20°C (68 °F): about 45 min
  • compressive strength after 28 d: ≥ 50 N/mm²
CE markingQDB certificate of conformity DAfStb/VeBMR
FD/20

Request test certificates

If you need further test certificates, please do not hesitate to contact us.
Tel. +49 201 685040
Email: pruefzeugnisse@pagel.de

Please enter your name.
Please enter a subject.
Please enter a valid phone number.
Please enter a message.

I have read the data protection declaration and I consent to the data I have provided being electronically collected and stored. My data is used only strictly for the processing and answering of my request.

You must accept the Terms and Conditions.

properties

  • ready-to-use (just mix with water) repair mortar suitable for facilities containig or processing substances hazardous to water
  • reduces the penetration of CO2 and humidity (anti-carbonation), to great extent oil and water resistant, at the same time provided with large reserves of alkali, actively protecting the reinforcement against corrosion
  • soft plastic processing texture and very good firmness on vertical and horizontal surfaces, also overhead
  • allows vapour diffusion
  • high frost and de-icing salt resistance
  • supplied as system comprising the following components:

fields of application

  • restoration of the impermeability to liquids in concrete facilities which store, bottle or process stationary liquids hazardous to water and to concrete, up to 144 hours
  • mortar system for protection against liquids hazardous to water, for determined construction thicknesses, for indoor and outdoor uses
  • suitable for traffic areas (pneumatic and vulkollan tyres)
  • structural and non-structural restoration of civil engineer facilities for storage, bottling and processing liquids hazardous to water classified as "medium"
  • Restoration of impermeability of concrete to hazardous liquids hazardous to water, for instance in refuelling and defuelling petrol stations, for motor, rail, water and air vehicles